XKC-C362 high and low level controller and XKC-Y26-V liquid level detection head realize the function of liquid level high and low control: when the container liquid level is too low, the low liquid level alarm signal sent by the low liquid level sensor is triggered to trigger the C362 controller to close the relay to start the water pump Add the liquid level, when the liquid level reaches a certain height, the high liquid level sensor sends out a signal to trigger the C362 controller to disconnect the relay and automatically stop the water pump to work in a cycle. Thereby, the function of automatic control of the container liquid level is realized, and the container liquid level is kept stable.
Product Features:
1. AC180V~250V power supply 2. Relay dry node output, suitable for various load control3. The control is diversified, and the pump can be controlled in manual or automatic mode4. The installation is simple and convenient, it can be installed with screws or electric box tracks
Technical Parameters:
1.Input voltage: AC180V-250V, 50/60Hz2.Working current: Working current ?110 mA, static current consumption ?20mA3.Load power: Resistive load below 500W (overload or three-phase load needs to be installed with AC contactor)4. Alarm Output: 500W (resistive load)5.input signal:Low sensor signal input;High-position sensing signal input;6.Operating temperature: -10~75?7.Dimensions: 115*90*40 mm
Package includes:
1 x Liquid Level Controller with 3 sensors
Basic function introduction:
Function:
1. Automatic water level control: the water level rises to a high level, the water pump is automatically started, and the water level is lower than the low level sensor probe, and the water pump is automatically turned off. (Automatic drainage)3. Manual automatic switching: The controller enters the automatic working mode by default when it is turned on. Press the K1 key to switch the working mode. The red light is on for automatic mode, and the red light is off for manual mode.4. Water inlet pipe abnormal alarm: When the controller starts to pump water automatically, and the water inlet pipe probe cannot detect water within a certain period of time (within 10 to 30 seconds), the load output relay is disconnected to stop pumping, and the alarm output relay is closed.5. Abnormal water overflow alarm: the controller starts to pump water automatically, and when the water surface rises to the position of the overflow alarm probe, the load output relay is disconnected to stop pumping, and the alarm output relay is closed.6. Abnormal low probe alarm: the controller starts to pump water automatically. If the low probe fails or falls off, and the water surface rises to the high probe position, the load output relay is disconnected to stop pumping, and the alarm output relay is closed.
Recommended wiring and application diagram
XKC-C362-3P wiring diagramThe following figure uses the high and low water level controller XKC-C362 + 3 XKC-Y26-V non-contact liquid level sensors to realize functions such as automatic water level control and water pump idling protection.