Description
Specifications:Model: SHT2000Supply voltage: AC 110~230V Power supply frequency: 50/60HzTemperature range: -20~60°C Humidity range: 0%~100%RHTemperature measurement accuracy: 0.3 °C Humidity measurement accuracy: 3%Output Control: Relay Output Output Power: MAX 10A Setting:
Setting method: Start value <stop value (program automatically determines working mode is heating/humidifying mode)Setting method: Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode)Heating/cooling mode settingSetting mode: setting (starting temperature): Press and hold the ? button to start the temperature flashing. Use ?? key to set the starting temperature value.Setting (stop temperature): Press and hold the ? button to stop the temperature flashing. Use ?? to set the stop temperature value. Heating use case: control the water heater, heat to 65 ° C to stop, the temperature drops back to 50 ° C and start heating againThe first step: heating mode, starting temperature <stop temperatureStep 2: Press and hold the ? button to start the temperature flashing. Use ?? to set the starting temperature to 50 °C.Step 3: Press and hold the ? button to stop the temperature flashing. Set the stop temperature to 65 °C with ?? keys, and the setting is completed!Refrigeration use case: use in the farm, the fan is ventilated to 26 ° C to stop, the temperature is raised to 30 ° C and the ventilation is started again.The first step: cooling mode, starting temperature > stop temperatureStep 2: Press and hold the ? button to start the temperature flashing. Use ?? to set the starting temperature to 30 °C.Step 3: Press and hold the ? button to stop the temperature flashing. Use ?? to set the stop temperature to 26°C. The setting is completed! Humidification/Dehumidification Mode Settings:Setting (start humidity): Press and hold ? key to start the humidity value flashing. Set the humidity value by ? ? key. Set [Stop Humidity]: Press and hold ? key to stop the humidity value flashing, and set the humidity to stop by ? ? key value. Humidification example: fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification. Setup steps: Step 1: Press and hold the ? button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50% RH. The second step: long press the ? button for 3 seconds to stop the humidity value flashing, set the value to 80% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state. Dehumidification example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidificationSetup steps: Step 1: Press and hold the ? button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 40% RH. Step 2: Press and hold the ? button for 3 seconds to stop the humidity value flashing, set the value to 70% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state. Package Inlcuded:
1 x SHT2000 Digital Temperature Humidity Controller AC110V 220V1 x Sensor Cable