Description
Specifications:Product model: ZFX-W1605Humidity measurement range: 1% RH ~ 99% RHHumidity measurement accuracy: 1% RHResolution: 0.1Humidity control range: 00% RH ~ 99% RHHumidity control accuracy: 1% RHTransmission line: L = 1mPower supply voltage: DC 12V / DC 24-60V / AC 220VApplicable environment: -25 ~ 55 ?, humidity 90% RH (no condensation)Output type: direct outputDiameter: 86mm
Setting:
1. In the setting mode, long press the SET button for 5 seconds, P0 will be displayed, and short press the SET button to switch the H / C (H is humidification, C is dehumidification)2. Set the stop humidity, press the SET button once, the screen flashes, and press the up and down keys to directly set the required humidity3. Press and hold the SET button for 5 seconds to display P0, press the up and down buttons to switch to P1, and then press the SET button once again to set the return difference (press the up and down buttons to adjust)If the humidification mode wants to be set between 35 and 37, then the stop humidity is set to 37, then the hysteresis must be set to 24. Indicator light: SET light is on, indicating that the parameter is being set: OUT indicator flashes to indicate the start delay, and constant light indicates the output5. Nixie tube: display LLL as sensor abnormality: display HHH as sensor causing short circuit or exceeding measurement range, when humidity is blinking, it is in the setting or alarm state.
ParameterFeaturesRangeDefaultsP0Operating modeHumidification / DehumidificationHP1Backlash setting1~20%RH2P2Humidity correct-20~20%RH0?P3Delayed start0~10min 0minP4High humidity alarmP6~99%RH 99%RHP5Low humidity alarm0~P6 %RH20%RHP6 Data lockOFF/ON OFF
P0: Humidification and dehumidification mode H / CStart with low humidity in humidification mode, set to H, for example, the actual humidity is 20% RH, you need to control the humidity between 35 ~ 37% RH, we set P0 to H humidification modeStart with high humidity in cooling mode, set to C, for example, the actual humidity is 38% RH, need to control the temperature between 23 ~ 27% RH, we set PO to C dehumidification modeP1: Hysteresis settingIn humidification mode: To control a humidity in the range of 37% RH ~ 39% RH, the actual humidity is less than this range, for example 25% RH, it is necessary to set to humidification mode H, stop humidity is set to 39% RH, P1 setting 2 (set stop humidity 39% RH-hysteresis = start humidity 39% RH), that is, if the humidity is lower than 37% RH, start higher than 39% RH and stopIn dehumidification mode: to control the range between 25% RH ~ 27% RH, the actual humidity is 37% RH, the actual humidity is higher than this range, it is necessary to set to dehumidification mode C, stop humidity is set to 25% RH, P1 setting 2 (set stop humidity 25% RH + hysteresis 2 = start humidity 27% RH), that is, humidity above 27% RH start below 25% RHP2: Humidity correction: humidity after correction (P2) = humidity before correction + correction valueP3: Delay start: After setting, the controller will not start immediately when it is output, and it will start only after the time you set (non-compressor)Control can be set to 0)P4: High humidity alarm: when the measured value is greater than the set alarm value, the screen flashes and there is a drop alarm sound,P5: Low humidity alarm: when the measured value is less than the set alarm value, the screen flashes and there is a drop alarm sound,P6: Data lock function: P6 is adjusted to ON to save the currently set parameters without modification.
Package Included:
1 x ZFX-W1605 Intelligent Humidity Controller1 x Sensor Cable