Description
Description:JDY-40 is developed with 2.4G technology, the sight distance is 120 meters, using serial port communication interface, using simple and fast, only need to understand the serial knowledge of the JDY-40 can be applied to the product!
Pin function description:
PinThe name of the disciplineFunction1GPI01Input-output IO, which can be configured by AT+CLSS2GPI02Input-output IO, which can be configured by AT+CLSS3GPI03Input-output IO, which can be configured by AT+CLSS4GPI04Input-output IO, which can be configured by AT+CLSS5GPI05Input-output IO, which can be configured by AT+CLSS6GPI06Input-output IO, which can be configured by AT+CLSS7GPI07Input-output IO, which can be configured by AT+CLSS8GPI08Input-output IO, which can be configured by AT+CLSS9VCCPower supply (2.2-3.6)10RXDSerial port input pin11TXDSerial port output pin12SETAT command switching pin (low level AT instruction, high level transparent transmission)13CSTransmission or push button mode: CS pin (low level wake-up, high level sleep).
IO receive mode:the CS pin needs to be suspended or pulled up14GNDPower supply
Application scene:
1:2.4G panel switch
2:2.4G remote control
3:2.4G transmission
4: one to many control of mobile phone
5:IO switching control
6:2.4G toys
7: smart home control application
Technical parameter:
ModelJDY-40Working band2.4GEmissive powerMaximum 12dBworking temperature-40 C - 80 CReception sensitivity-97dbtransmission distance120 metersworking voltage2.2V-3.6VTX current40mARX current24mASleep current5uAcommunication interfaceStandard TTL serial port
Default configuration:
sequencefunctionparameterinstructions1baud rate9600AT+BAUD2wireless ID8899AT+RFID88993device ID1122AT+DVID11224channel001AT+RFC0015emissive power12dbAT+POWE96equipment typeA0AT+CLSSA0
Communication:
it is necessary to configure the RFC, DVID, and RFID that need the communication module to be the same. The module and the module can communicate. When the module comes out, the parameters are all unified, and the user can configure it according to its own needs.
AT instruction instructions:
Specifically, the JDY-40 module needs to add the ending symbol rn to send the AT instruction.
Set / query - baud rate:
instructionsresponseresponse
AT+BAUD
OKParam(1-7)
1:1200
2:2400
3:4800
4:9600
5:14400
6:19200
Default value:4
AT+BAUD
+BAUD=
Set / query -RFID:
instructionsresponseresponseAT+RFIDOKParam(0000-FFFF)
Default value:8899AT+RFID+BAUD=
Set / query -DVID:
instructionsresponseresponseAT+DVIDOKParam(0000-FFFF)
Default value:8899AT+DVID+BAUD=
Set / query -RFC:
instructionsresponseresponseAT+RFCOKParam(001-128)
Default value:001AT+RFC+RFC=
Set / query -POWE:
instructionsresponseresponse
AT+POWE
OKParam(0-9)
0:-25db
1:-15db
2:-5db
3:0db
4:+3db
5:+6db
6:+9db
7:+10db
8:+10db
9:+12db
Default value:9
AT+POWE
+POWE=
Set / query -CLSS:
instructionsresponseresponse
AT+CLSS
OKParam
A0:serial port transmission (transceiver)
C0: remote control or IO button with indicator (transmitter).
C 1: remote control or IO button without indicator (transmitter).
C 2:IO normally high level, after receiving the signal, low level, delay.
High level after 30mS
C 3:IO is usually low level, after receiving the signal, the high level has been
Recovery of low level after delayed 30mS
C 4:IO is usually low level, and receives the high level of the pressed signal.
Receive raised signal low level
The IO level is reversed when the C 5:IO receives the pressed signal.
Default value: A0
AT+CLSS
+CLSS=
Package included:
5 x JDY-40 2.4G Wireless Serial Port Transmission And Transceiver Integrated Remote Communication Module